ZERO CROSS OVER DC TO AC SOLID STATE RELAY (UL APPROVED)
25A
40A
50A
90A
150A
200A
901 MODEL / HEATSINK | 25 AMP SSR LOAD CURRENT @ 40°C |
---|---|
Without Heat sink | 10 Amp |
C-56 | 12 Amp |
G-68 | 16 Amp |
UNI 901 ZDA 48 25 01 AL5 + DIN RAIL
Lowest thickness 22.5mm with 5mm Aluminium Plate
Input : 4-32VDC / 4-16mA
Input Green LED Indication
Output : 24-480VAC (47-63 Hz), 25 Amp
PIV : 800, I²T : 340A²S for 9.6mS
Zero Cross Over SSR design
Body insulation : 6kV for 1min
I/P. to O/P. insulation : 6kV for 1min
Inbuilt surge voltage protection of 2700Vrms
Long life cycle Up to 10¹¹ cycles
UNI 901 ZDA 48 25 01 AL5 + DIN RAIL
901 MODEL / HEATSINK | 40 AMP SSR LOAD CURRENT @ 40°C |
---|---|
Without Heat sink | 12 Amp |
C-56 | 14 Amp |
G-68 | 18 Amp |
UNI 901 ZDA 48 40 01 C56 + DIN RAIL
Lowest thickness 22.5mm with 5mm Aluminium Plate
Input : 4-32VDC / 4-16mA
Input Green LED Indication
Output : 24-480VAC (47-63 Hz), 40 Amp
PIV : 800, I²T : 880A²S for 9.6mS
Zero Cross Over SSR design
Body insulation : 6kV for 1min
I/P. to O/P. insulation : 6kV for 1min
Inbuilt surge voltage protection of 2700Vrms
Long life cycle Up to 10¹¹ cycles
UNI 901 ZDA 48 40 01 C56 + DIN RAIL
901 MODEL / HEATSINK | 50 AMP SSR LOAD CURRENT @ 40°C |
---|---|
Without Heat sink | 12 Amp |
C-56 | 16 Amp |
G-68 | 26 Amp |
B-48 | 32 Amp |
UNI 901 ZDA 60 50 01 AL5 + G-68 HEAT SINK + DIN RAIL
Lowest thickness 22.5mm with 5mm Aluminium Plate
Input : 4-32VDC / 4-16mA, Green LED indication
O/P: 24-600VAC(47-63 Hz), 50 Amp (Zero cross over)
PIV : 1600, I²T : 3000A²S for 9.6mS
Body insulation : 6kV for 1min
I/P. to O/P. insulation : 8kV for 1min
Inbuilt surge voltage protection of 2700Vrms
Short Circuit Protection by “B” Curve DP MCB
Resistive load Max 15 A SC protect by 16 A DP MCB
Short Circuit Current Rating : 10kA for <3mS
UNI 901 ZDA 60 50 01 AL5 + G-68 HEAT SINK + DIN RAIL
901 MODEL / HEATSINK | 90 AMP SSR LOAD CURRENT @ 40°C |
---|---|
B-48 | 36 Amp |
B-72 | 60 Amp |
A-100 | 65 Amp |
A-190 Heat Sink without Fan | 36 A x 3 = 108 Amp |
A-190 Heat Sink with Fan | 40 A x 3 = 120 Amp |
UNI 901 ZDA 60 90 01 CU2 + B-48 HEAT SINK + DIN RAIL
Lowest thickness 19.5mm with 2mm Copper Plate
Input : 4-32VDC / 4-16mA, Green LED indication
O/P: 24-600VAC(47-63 Hz), 90 Amp (Zero cross over)
PIV : 1600, I²T : 7200A²S for 9.6mS
Body insulation : 6kV for 1min
I/P. to O/P. insulation : 8kV for 1min
Inbuilt surge voltage protection of 2700Vrms
Short Circuit Protection by “B” Curve DP MCB
Resistive load Max 63 A SC protect by 63 A DP MCB
Short Circuit Current Rating : 10kA for <3mS
UNI 901 ZDA 60 90 01 CU2 + B-48 HEAT SINK + DIN RAIL
901 MODEL / HEATSINK | 150 AMP SSR LOAD CURRENT @ 40°C |
---|---|
A-100 | 75 Amp |
A-190 Heat Sink without Fan | 40 A x 3 = 120 Amp |
A-190 Heat Sink with Fan | 45 A x 3 = 135 Amp |
UNI 901 ZDA 60 150 01 CU2 + B-72 HEAT SINK + DIN RAIL
Lowest thickness 19.5mm with 2mm Copper Plate
Input : 4-32VDC / 4-16mA, Green LED indication
O/P: 24-600VAC(47-63 Hz), 150Amp (Zero cross over)
PIV : 1600, I²T : 15000A²S for 9.6mS
Body insulation : 6kV for 1min
I/P. to O/P. insulation : 8kV for 1min
Inbuilt surge voltage protection of 2700Vrms
Short Circuit Protection by “B” Curve DP MCB
Resistive load Max 80 A SC protect by 80 A DP MCB
Short Circuit Current Rating : 10kA for <3mS
UNI 901 ZDA 60 150 01 CU2 + B-72 HEAT SINK + DIN RAIL
901 MODEL / HEATSINK | 200 AMP SSR LOAD CURRENT @ 40°C |
---|---|
A-100 | 80 Amp |
A-190 Heat Sink without Fan | 44 A x 3 = 132 Amp |
A-190 Heat Sink with Fan | 52 A x 3 = 156 Amp |
UNI 901 ZDA 60 200 01 CU2 + A-100 HET SINK + DIN RAIL
Lowest thickness 19.5mm with 2mm Copper Plate
Input : 4-32VDC / 4-16mA, Green LED indication
O/P: 24-600VAC(47-63 Hz), 200Amp (Zero cross over)
PIV : 1600, I²T : 25000A²S for 9.6mS
Body insulation : 6kV for 1min
I/P. to O/P. insulation : 8kV for 1min
Inbuilt surge voltage protection of 2700Vrms
Short Circuit Protection by “B” Curve DP MCB
Resistive load Max 115A SC protect by 125A DP MCB
Short Circuit Current Rating : 10kA for <3mS